Netapp NS0-520 - NetApp Certified Implementation Engineer - SAN ONTAP Exam

Page:    1 / 12   
Total 60 questions

A customer wants to deploy NVMe/FC along with an existing FC SAN fabric using ONTAP 9.8.
In this scenario, which two actions are correct? (Choose two.)

  • A. Enable NVMe/FC on the existing FC SVM.
  • B. Create new zoning on fabric switches.
  • C. Upgrade your FC switches from 16 GB to 32 GB.
  • D. Use existing zoning on fabric switches.


Answer : CD

Click the Exhibit button.

You are configuring a new NetApp ONTAP cluster and are connecting the nodes to Cisco MDS SAN switches. You connect one of the nodes to switch port fc1/11 and run the commands that are shown in the exhibit. The SAN LIFs are enabled but are not operationally online, and none of the SAN hosts can access their LUNs on the ONTAP cluster.
In this scenario, which configuration would cause this problem?

  • A. NPIV is not enabled on the switches.
  • B. Interoperability mode is not enabled on the switches.
  • C. NPV is not enabled on the switches.
  • D. The in-order guarantee is not enabled on the switch.


Answer : B

You are installing an AFF A250 system with ONTAP 9.8 software. Your customer asks you about the recommended LIF configuration for the iSCSI protocol.
In this scenario, which two statements are correct? (Choose two.)

  • A. Each node in an iSCSI configuration must be connected to a minimum of two Ethernet switches.
  • B. Each SVM in an iSCSI configuration must have a minimum of two LIFs per node.
  • C. All LIFs from the SVM are connected to a single Ethernet switch.
  • D. Each SVM in an iSCSI configuration must have a minimum of one LIF per node.


Answer : AC

A customer has a 4-node cluster consisting of a FAS8020 system and an AFF A220 system that is running iSCSI workloads across two separate SVMs. The FAS8020 system is reaching end of support, so they add a new AFF A400 system to migrate workloads off the FAS8020 system. The customer wants to migrate data off the FAS8020 aggregate n1_aggr1 on SVM2 to the AFF A400 aggregate n5_aggr1 on SVM1.
In this scenario, which NetApp command would accomplish this task?

  • A. volume move
  • B. aggregate reallocation
  • C. volume reallocation
  • D. volume rehost


Answer : D

Which NetApp tool provides a detailed inventory of SAN components?

  • A. Hardware Universe
  • B. Active IQ Config Advisor
  • C. Interoperability Matrix Tool
  • D. Active IQ OneCollect


Answer : C

Page:    1 / 12   
Total 60 questions