HP HPE0-S46 - Architecting HPE Server Solutions Exam

Page:    1 / 12   
Total 60 questions

A customer plans to enable support automation on a HPE ProLiant G7 server using Insight
Remote Support with HPE Proactive Care services.
What should the customer do prior to registering its servers for Insight Remote Support?

  • A. Open the incoming network port 7906 for the servers.
  • B. Enable iLO Federation.
  • C. Link a contract to the Insight Online.
  • D. Install an SNMP agent.


Answer : D

Explanation:
If you use SNMP Agents or WBEM Providers you must stilladd RIBCL protocol credentials in the Insight RS Console; RIBCL is required for AHS Collections and for Insight RS to monitor the server.

A customer is using an HPE BladeSystem c7000 enclosure with Virtual Connect 20/40 F8 modules. The customer plans to improve network redundancy between the VC modules by creating LACP aggregated links from each single VC module to two different physical ToR switches.
Which HPE networking technology should the architect recommend to the customer?

  • A. intelligent Resilient Framework (IRF)
  • B. Spanning Tree Protocol (STP)
  • C. Multiple Spanning Tree Protocol (MSTP)
  • D. Open Shortest Path First (OSPF)


Answer : D

Select all that apply.
Drag each HPE Proliant rack server profile on the left to the matching description in the right.




Answer :

Which high availability option is available only for HPE ProLiant Gen9 servers?

  • A. HPE Ultrium tape blades
  • B. HPE Smart Storage battery
  • C. HPE StoreOnce Backup
  • D. ProLiant System ROM backup version


Answer : B

An architect is working with a customer to design a new data center that can take advantage of free-cooling.
Which HPE solution should the architect recommend to the customer?

  • A. ASHRAE A4 compliant HPE ProLiant Gen9 servers
  • B. HPE Intelligent Power Distribution Units (iPDU)
  • C. HPE ProLiant Gen9 servers with 96 percent (Titanium) efficiency power supplies
  • D. HPE Modular Cooling System server cabinets


Answer : A

Explanation:
There are many regions throughout the world where the outdoor temperature remains cool and the humidity is low enough for several months of the year to take advantage of free cooling for the data center. The Green Grid white paper #46, Updated Air-Side Free
Cooling Maps: The Impact of ASHRAE 2011 Allowable Ranges, estimates the number of hours that can be used for free cooling in different regions of North America, Europe and
Japan.

Page:    1 / 12   