An engineer has installed an SC8000 with 15K drives in Tier 1, and 7K drives in Tier 3. The volume is created using the recommended storage profile. A replay is taken after the initial data is imported, which results in On Demand Data Progression running.
What is going to happen to the data?
Answer : C
An engineer has installed an SC4020 with four FC ports in each controller. This is a dual- fabric installation with four FC connections in each server. The servers use the OS built-in multi-pathing capabilities.
Which two configurations will cause the controller failover to fail? (Choose two.)
Answer : B,D
How are replay scheduling rules applied to a particular volume?
Answer : A
An engineer updates the SCOS version from 6.5.x to 6.6.x on an SC4020 via ISO. The engineer uses the following credentials: admin / admin. The engineer calls Dell Support for final health checks and is informed that a newer SCOS 6.6.x version is available. The engineer tries to perform another ISO update to the newest SCOS 6.6.x version. The engineer is unable to log back in to the BMC interface to start the ISO update.
What should the engineer do to update the newest SCOS version via ISO?
Answer : A
On the first day after the Storage Center is installed, the engineer begins copying data to it.
The engineer uses the default Replay Profile and Data Progression settings. The engineer notices that the system did take replays, but no data has been restriped in Tier 1.
What is the cause of the problem?
Answer : C